Is the sCMOS too good to be true?

Posted 6/18/2009 0 comments

While the sCMOS technology from Andor, Fairchild, and PCO  may seem too good to be true, it actually isn’t. That's because the advance fits right into the progression of sensor technology in recent years.

There’s a lot of good information on the factors driving the CCD vs. CMOS market at this link.  The short and simple version of recent sensor history is that CMOS performance has generally been worse than CCDs and thus wasn’t heavily used in challenging scientific imaging. CMOS has slowly (more quickly in recent years) creeped up in quality, and in fact, several have entered the life sciences market in the last three years. However, most have had trouble with noise and thus aren’t as sensitive as CCDs.

It seems like these three companies put their heads together to give CMOS that one last push in performance, which was needed to make it a truly usable alternative to CCDs in the highly demand world of scientific imaging. In my time working in this industry I have never heard of three companies working together in this way, and I think it is great that they pushed this technology ahead.

Those of you that aren’t really sure what’s on the inside of your microscope’s camera might be asking why these companies would work together on something like this. The collaboration makes sense because cameras from different companies often (but not always) use exactly the same imaging chips inside. Each company optimizes the camera’s cooling, software, and data connections to the specifications they think are most important for the applications the camera is targeting.

The new sCMOS will compete with one of the more recent image sensor developments – the hybrid CCD/CMOS. This technology was introduced in the last few years and is designed to overcome the drawbacks of each type of sensor. The collaborating companies say that the new CMOS technology is less complex and less expensive to manufacturer that the hybrid sensors. I haven’t seen the hybrid technology widely available in actual cameras yet.

Since the white paper gives detailed analysis of the sCMOS with EMCCD and interline CCD cameras, here’s a look at how the specs for the new CMOS lined up with a current CMOS cameras on the market.

I’m not sure if the PCO 1200 hs CMOS camera is the best CMOS camera out today, but I know it is finding some life science applications. Some of its highlights are 1280 X 1024 resolution, 12.0 X 12.0 um2 pixel size, 85 e- rms, 27 % peak quantum efficiency. To compare the new sCMOS has 2560(h) x 2160(v) resolution, 6.5 μm pixel size, <>

It’s always exciting to see a new technology like this, especially one that is driven by the scientific market when so often other markets drive image sensor technology. We won’t know the true implications of this new technology until the cameras using it come out next year.

Read the original post on sCMOS here.
More information on this technology at www.scmos.com.

Less embryo phototoxicity with spinning disk/EMCCD microscopy setup

Posted 3/30/2009 0 comments
Electron multiplying (EM) CCD cameras have helped spinning disk confocal microscopy find more use because the cameras are sensitive enough to detect the low levels of light produced by the microscopy method. For living specimens, this type of microscopy brings the benefits of reducing phototoxicity during the repeated exposures used to acquire time-lapse images or z-axis slices.

Researchers at RIKEN-Kobe in Japan recently used this win-win technology pairing to image mouse embryos. They published a paper in the Journal of Reproduction and Development describing how their methods decreased phototoxicity so much that preimplantation mouse embryos could undergo long-term time-lapse imaging, be implanted, and then survive full-term.

They used an Olympus inverted microscope with a Nipkow disk confocal module and an Andor EMCCD camera. A CVI Melles Griot 70 mW agron-krypton laser provided the confocal light source. The mouse embryos were injected with a mixture of mRNAs encoding for enhanced GFP coupled to alpha-tublin and monomeric RFP fused to histone H2B. At specific time points, the researchers acquired 51 images in the z-axis with 488 and 561 nm excitation. Imaging took place for 70 hours.

Although the setup lessened light exposure, the researchers found that the interval between observations was another important factor -- an interval of 7.5 min. increased embryo viability greatly over 3.75 minutes. They also found that continuous light exposure was worse than repeated intermittent excitation, even when the total exposure was equal.

This microscopy method could aid study of development and assistive reproductive techniques in mammals. For example, it could help reveal why some assistive reproductive techniques (such as in vitro fertilization) work better than others, and it might be used to identify healthy embryos prior to implantation.

In the paper, the researchers pointed out that the mechanisms behind phototoxicity are still not completely understood and that their findings regarding phototoxicity imply that embryos may be able to neutralize toxicity. To find out more about this topic, I am going to compile some of the latest research on photoxicity.

Are you performing research in the area of phototoxicity, or do you know of a good resource?

Image: These time-lapse images show spindle (green) and nuclear (red) dynamics during preimplantation embryo development. Courtesy of Kazuo Yamagata, RIKEN-Kobe.

Note: If you want to know more about EMCCDs, Photometrics is holding webinar covering this topic on Friday April 3: http://tinyurl.com/cwarev.

 

Microscopy News © 2008 using D'Bluez Theme Designed by Ipiet Supported by Tadpole's Notez Based on FREEmium theme Blogger Templates